How to Prepare a Nutrient Solution

A nutrient solution is water with dissolved fertilizer at a concentration suitable for watering. Through it the plant receives mineral elements. The composition of the solution is chosen taking into account the source water, the substrate, and the needs of the plant.

To prepare it you need a container of known volume, water, fertilizer, and an accurate measuring tool: a syringe or measuring cup for liquid products, and scales for powders. With controlled feeding, EC and pH meters are also used.

Choose the water and the fertilizer

The source water already contains dissolved substances. When fertilizer is added, they become part of the overall composition of the solution. That is why the same dose in tap water and in reverse osmosis water can give different EC and pH readings.

If the water is blended with reverse osmosis water, first prepare the required water blend, then add the nutrients. Choosing a source is covered in more detail in the article "Water sources, mineral content, and hardness".

The fertilizer is chosen to suit the growing system. In a substrate with built-in nutrients, feeding supplements the existing reserve. In hydroponics, the solution must provide the plant with the full set of necessary elements.

When reverse osmosis water is used, check separately where the plant will get its calcium and magnesium from. They may already be part of the base fertilizer. An additional CalMag — a calcium and magnesium supplement — is used when it is needed based on the composition of the water and the feeding program.

Calculate the amount of fertilizer

The dose is recalculated for the actual volume of water.

For example, if the chosen dose is 1 ml per liter, a watering can with 3 liters of water will need 3 ml of fertilizer. This is an example of the calculation, not a universal feeding rate.

For a multi-part fertilizer, the amount of each part is calculated separately. If the program calls for 1 ml/L of part A and 1 ml/L of part B, then for 3 liters of water you take 3 ml of each part.

Liquid products are measured in milliliters and powders in grams. These units cannot be substituted for each other: the mass depends on the density of the product.

In what order to mix

The order of the individual components is determined by the manufacturer of the chosen product line. This is especially important for multi-part nutrients, silicon products, and calcium-magnesium supplements.

The general sequence:

  1. Measure out the water. Use water at a suitable temperature, without a sharp difference from the root zone.
  2. Add the components called for in the program one at a time. After each addition, mix the solution thoroughly.
  3. Wait for it to dissolve. Water-soluble powders must dissolve before the next product is added.
  4. Check the concentration. Measure the EC of the finished solution if feeding is done with conductivity control.
  5. Measure the pH and adjust it if necessary.
  6. Mix again and check the final readings.

Parts A and B, as well as other concentrates, are not combined in the measuring cup before being added to the water. When high concentrations come into direct contact, some substances can form poorly soluble compounds and precipitate. Each part is introduced separately into the main volume of water.

Additional products are included in the solution only with a clear purpose and confirmed compatibility.

Check the concentration by EC

EC shows the electrical conductivity of the solution and helps estimate the total content of dissolved ions. Measuring it is useful when changing the water or the fertilizer, preparing a new mix, and growing in systems where all nutrition comes from the solution.

First take into account the EC of the source water, then check the finished solution. When comparing with the manufacturer's program, find out whether it gives the final EC or the increase over the source water reading.

If the concentration is higher than chosen, dilute the solution with suitable water, mix, and measure again. If it is lower, add fertilizer in small measured portions, keeping the intended ratio of components.

You must not reach the target number by arbitrarily adding one product: the same EC can correspond to a different nutrient composition.

Units of measurement, how meters work, and how EC relates to ppm are explained in the article "EC, TDS, and ppm".

When to adjust pH

The final pH is checked after the solution has been prepared: fertilizers and additives change the reaction of the water.

If the reading falls outside the chosen working range, use pH Down to lower or pH Up to raise the pH. These are special acidity adjusters. They are added in small portions according to the instructions, mixing the solution each time and waiting for a stable reading on the meter.

If the manufacturer calls for pre-treating the water, it is done at the specified stage. The final check is still done after all components have been added.

The required range, measurement methods, and meter calibration are covered in the article "pH of water and solution".

Before watering

Check whether the fertilizer has dissolved completely and whether any unexpected flakes or sediment have appeared. With a new combination of products, it is convenient to prepare a small test batch first.

To repeat a successful mix, it is enough to write down:

A solution for a one-time feeding is best prepared in the amount needed for the current watering. Whether it can be stored depends on the composition and the manufacturer's instructions; be especially careful about this when organic and biological products are added.